πŸ“ž +91-7667918914 | βœ‰οΈ ijireeice@gmail.com
International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering
International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering A monthly Peer-reviewed & Refereed journal
ISSN Online 2321-2004ISSN Print 2321-5526Since 2013
IJIREEICE meets the suggestive parameters outlined in the latest University Grants Commission (UGC) for peer-reviewed journals, ensuring high standards of research integrity, publication ethics, and academic excellence.
← Back to VOLUME 1, ISSUE 6, SEPTEMBER 2013

Enhanced Loadability of Existing Ehvac Line by Combined Ac-Dc Transmission System

Y.PRAVEEN KUMAR REDDY, K.SHOBHA RANI, N.G.V.SATYA KUMAR, P.NAGARJUNA, P.SRAVANTHI

πŸ‘ 1 viewπŸ“₯ 0 downloads
Share: 𝕏 f in ✈ βœ‰
Abstract: Now-a-days, demand for electric power has shown steady but geographically uneven growth.The wheeling of the available energy through existing long ac lines to load centers has a certain upper limit due to stability considerations. Thermal limit is the major limit to be considered while increasing loadability of existing EHV long transmission lines. Thus, these lines cannot be loaded to their thermal limit to keep sufficient margin against transient instability. This paper presents the concept of composite ac-dc power transmission. The conductors are allowed to carry usual ac along with dc superimposed on it. This will load the transmission lines close to its thermal limit thereby increasing the stability of the system. This paper presents the feasibility of converting a double circuit ac line into composite ac–dc power transmission line to get the advantages of parallel ac–dc transmission to improve stability and damping out oscillations. No alterations of conductors, insulator strings, and towers of the original line are needed. The proposed scheme is digitally simulated with the help of MATLAB software package. Simulation results clearly indicate the substantial increase in loadability of existing EHV AC lines by combined ac-dc transmission.

Keywords: Extra high voltage (EHV) transmission, MATLAB simulation, simultaneous ac-dc transmission

How to Cite:

[1] Y.PRAVEEN KUMAR REDDY, K.SHOBHA RANI, N.G.V.SATYA KUMAR, P.NAGARJUNA, P.SRAVANTHI, β€œEnhanced Loadability of Existing Ehvac Line by Combined Ac-Dc Transmission System,” International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering (IJIREEICE)

Creative Commons License This work is licensed under a Creative Commons Attribution 4.0 International License.